#25068 - x/24/eighteen 01:31 PM KONE monospace stuck on fire service
Joined: Feb 2018
Posts: 56
workingclass Offline
journeyman
workingclass Offline
journeyman

Joined: Feb 2018
Posts: 56

I take a KONE monospace stuck on burn down service
Hall stage 1 switch is good, switch inside car works every bit it should (phase2 works unremarkably , hold works, and turning back to normal recalls to lobby)

Is there anything I would demand to do at the controller to remove information technology? Opening and closing the doors at the lobby does not accept information technology off smirk

Only mistake on controller is 2301 but both of my car station boards seem to work

Terminal edited by workingclass; ten/24/xviii 01:33 PM.

#25069 - ten/24/18 02:57 PM Re: KONE monospace stuck on fire service [Re: workingclass]
Joined: Jun 2017
Posts: 35
Norcan Offline
newbie
Norcan Offline
newbie

Joined: Jun 2017
Posts: 35

Off the summit of my head I think 2301 fault is that CPU is not seeing a hall board. Effort pulling the XM16 plug on the right side of the CPU and power off the main disconnect. Wait 30 seconds or and then. Power back up with XM16 plug still removed wait nigh 30 seconds and plug XM16 back in CPU will come live go back and try resetting the stage 1 central switch. Sometimes the sudden power surge when you power up from the disconnect volition lock up CPU.


#25073 - 10/24/18 07:09 PM Re: KONE monospace stuck on fire service [Re: workingclass]
Joined: Nov 2013
Posts: 93
koneisland Offline
journeyman
koneisland Offline
journeyman

Joined: November 2013
Posts: 93

Enter car call from MAP. Enter elevator and register a car call to the designated fire flooring.
When lift stops at fire flooring doors volition not open.
Press and hold door open button until elevator doors reach fully open position.
Fire control should now be reset.


#25079 - 10/24/18 x:36 PM Re: KONE monospace stuck on fire service [Re: workingclass]
Joined: Apr 2017
Posts: ninety
UpandDown2321 Offline
journeyman
UpandDown2321 Offline
journeyman

Joined: Apr 2017
Posts: 90

Sometimes you need to turn off burn service. 1-62 to 0 ability bike. Change back to ane and power bicycle.

Last edited by UpandDown2321; 10/24/18 10:36 PM.


How To Reset Fire Service On Kone Elevator,

Source: http://www.vatortrader.com/forums/ubbthreads.php?ubb=showflat&Number=25068

Posted by: fergusonsuffect.blogspot.com

Related Posts

0 Response to "How To Reset Fire Service On Kone Elevator"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel